Implantable cardiac defibrillators for people with non-ischaemic cardiomyopathy.
Cochrane Database Syst Rev. 2018 Dec 08;12:CD012738
Authors: El Moheb M, Nicolas J, Khamis AM, Iskandarani G, Akl EA, Refaat M
Abstract
BACKGROUND: There is evidence that implantable cardioverter-defibrillator (ICD) for primary prevention in people with an ischaemic cardiomyopathy improves survival rate. The evidence supporting this intervention in people with non-ischaemic cardiomyopathy is not as definitive, with the recently published DANISH trial finding no improvement in survival rate. A systematic review of all eligible studies was needed to evaluate the benefits and harms of using ICDs for primary prevention in people with non-ischaemic cardiomyopathy.
OBJECTIVES: To evaluate the benefits and harms of using compared to not using ICD for primary prevention in people with non-ischaemic cardiomyopathy receiving optimal medical therapy.
SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, and the Web of Science Core Collection on 10 October 2018. For ongoing or unpublished clinical trials, we searched the US National Institutes of Health Ongoing Trials Register ClinicalTrials.gov, the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP), and the ISRCTN registry. To identify economic evaluation studies, we conducted a separate search to 31 March 2015 of the NHS Economic Evaluation Database, and from March 2015 to October 2018 on MEDLINE and Embase.
SELECTION CRITERIA: We included randomised controlled trials involving adults with chronic non-ischaemic cardiomyopathy due to a left ventricular systolic dysfunction with an ejection fraction of 35% or less (New York Heart Association (NYHA) type I-IV). Participants in the intervention arm should have received ICD in addition to optimal medical therapy, while those in the control arm received optimal medical therapy alone. We included studies with cardiac resynchronisation therapy when it was appropriately balanced in the experimental and control groups.
DATA COLLECTION AND ANALYSIS: The primary outcomes were all-cause mortality, cardiovascular mortality, sudden cardiac death, and adverse events associated with the intervention. The secondary outcomes were non-cardiovascular death, health-related quality of life, hospitalisation for heart failure, first ICD-related hospitalisation, and cost. We abstracted the log (hazard ratio) and its variance from trial reports for time-to-event survival data. We extracted the raw data necessary to calculate the risk ratio. We summarised data on quality of life and cost-effectiveness narratively. We assessed the certainty of evidence for all outcomes using GRADE.
MAIN RESULTS: We identified six eligible randomised trials with a total of 3128 participants. The use of ICD plus optimal medical therapy versus optimal medical therapy alone decreases the risk of all-cause mortality (hazard ratio (HR) 0.78, 95% confidence interval (CI) 0.66 to 0.92; participants = 3128; studies = 6; high-certainty evidence). An average of 24 patients need to be treated with ICD to prevent one additional death from any cause (number needed to treat for an additional beneficial outcome (NNTB) = 24). Individuals younger than 65 derive more benefit than individuals older than 65 (HR 0.51, 95% CI 0.29 to 0.91; participants = 348; studies = 1) (NNTB = 10). When added to medical therapy, ICDs probably decrease cardiovascular mortality compared to not adding them (risk ratio (RR) 0.75, 95% CI 0.46 to 1.21; participants = 1781; studies = 4; moderate-certainty evidence) (possibility of both plausible benefit and no effect). Implantable cardioverter-defibrillator was also found to decrease sudden cardiac deaths (HR 0.45, 95% CI 0.29 to 0.70; participants = 1677; studies = 3; high-certainty evidence). An average of 25 patients need to be treated with an ICD to prevent one additional sudden cardiac death (NNTB = 25). We found that ICDs probably increase adverse events (possibility of both plausible harm and benefit), but likely have little or no effect on non-cardiovascular mortality (RR 1.17, 95% CI 0.81 to 1.68; participants = 1781; studies = 4; moderate-certainty evidence) (possibility of both plausible benefit and no effect). Finally, using ICD therapy probably has little or no effect on quality of life, however shocks from the device cause a deterioration in quality of life. No study reported the outcome of first ICD-related hospitalisations.
AUTHORS' CONCLUSIONS: The use of ICD in addition to medical therapy in people with non-ischaemic cardiomyopathy decreases all-cause mortality and sudden cardiac deaths and probably decreases mortality from cardiovascular causes compared to medical therapy alone. Their use probably increases the risk for adverse events. However, these devices come at a high cost, and shocks from ICDs cause a deterioration in quality of life.
PMID: 30537022 [PubMed - as supplied by publisher]
from PubMed via alexandrossfakianakis on Inoreader https://ift.tt/2Bg8hJ0
No comments:
Post a Comment