Blog Archive

Αλέξανδρος Γ. Σφακιανάκης

Saturday, December 15, 2018

Real-time Visualization of Breast Carcinoma in Pathology Specimens From Patients Receiving Fluorescent Tumor-Marking Agent Tozuleristide.

Real-time Visualization of Breast Carcinoma in Pathology Specimens From Patients Receiving Fluorescent Tumor-Marking Agent Tozuleristide.

Arch Pathol Lab Med. 2018 Dec 14;:

Authors: Dintzis SM, Hansen S, Harrington KM, Tan LC, Miller DM, Ishak L, Parrish-Novak J, Kittle D, Perry J, Gombotz C, Fortney T, Porenta S, Hales L, Calhoun KE, Anderson BO, Javid SH, Byrd DR

Abstract
CONTEXT.—: Resection of breast carcinoma with adequate margins reduces the risk of local recurrence and reoperation. Tozuleristide (BLZ-100) is an investigational peptide-fluorophore agent that may aid in intraoperative tumor detection and margin assessment. In this study, fluorescence imaging was conducted ex vivo on gross breast pathology specimens.
OBJECTIVES.—: To determine the potential of tozuleristide to detect breast carcinoma in fresh pathology specimens and the feasibility of fluorescence-guided intraoperative pathology assessment of surgical margins.
DESIGN.—: Twenty-three patients received an intravenous bolus dose of 6 or 12 mg of tozuleristide at least 1 hour before surgery. Fifteen lumpectomy and 12 mastectomy specimens were evaluated for fluorescence by the site's clinical pathology staff using the SIRIS, an investigational near-infrared imaging device. The breast tissue was then processed per usual procedures. Fluorescent patterns were correlated with the corresponding hematoxylin-eosin-stained sections. Clinical pathology reports were used to correlate fluorescent signal to grade, histotype, prognostic marker status, and margin measurements.
RESULTS.—: Tozuleristide fluorescence was readily observed in invasive and in situ breast carcinoma specimens. Most invasive carcinomas were bright and focal, whereas in situ lesions demonstrated a less intense, more diffuse pattern. Tozuleristide was detected in ductal and lobular carcinomas with a similar fluorescent pattern. Fluorescence was detected in high- and low-grade lesions, and molecular marker/hormone receptor status did not affect signal. Fluorescence could be used to identify the relationship of carcinoma to margins intraoperatively.
CONCLUSIONS.—: Tumor targeting with tozuleristide allowed visual real-time distinction between pathologically confirmed breast carcinoma and normal tissue.

PMID: 30550350 [PubMed - as supplied by publisher]



from PubMed via alexandrossfakianakis on Inoreader https://ift.tt/2Gi9Z2a

No comments:

Post a Comment