Blog Archive

Αλέξανδρος Γ. Σφακιανάκης

Tuesday, November 27, 2018

Evaluation of an Innovative Bleeding Cricothyrotomy Model.

Related Articles

Evaluation of an Innovative Bleeding Cricothyrotomy Model.

Cureus. 2018 Sep 18;10(9):e3327

Authors: Hughes KE, Biffar D, Ahanonu EO, Cahir TM, Hamilton A, Sakles JC

Abstract
Objectives Emergency medicine (EM) residents are required to perform a cricothyrotomy during training as per the Accreditation Council for Graduate Medical Education (ACGME) guidelines. Cricothyrotomy is a rare procedure, comprising 0.45% of emergency department airway management procedures. Procedural competence in utilizing a realistic trainer is of utmost importance. We have developed a cricothyrotomy trainer using a fused deposition modeling (FDM) three-dimensional (3D) printer and innovative bleeding tissue to enhance fidelity. We aim to evaluate the trainer's realism. Methods Implementation occurred during a difficult airway educational lab for EM residents in April 2018. Participants completed anonymous written surveys after performing a cricothyrotomy on the trainer. The survey evaluated the realism of the trainer and compared it to other available models by utilizing five-point visual analog scales (VAS). The participants rated their comfort level in performing the procedure pre- and post-educational lab on a five-point VAS. Demographic data included postgraduate year, prior clinical cricothyrotomy experience as a primary operator versus as an assistant, and previous trainer experience. The survey included open-response suggestions for trainer improvement.  Results Forty-three EM residents completed the survey (82.7%, 43/52). The mean realism rating of the trainer was 3.81 (95% CI = 3.54-4.1). The participants reported previous training on cadaver (62.8%, 27/43), porcine (46.5%, 20/43), and manikin (67.4%, 29/43) models prior to using this trainer. The bleeding cricothyrotomy trainer was rated higher than other models (4.45, 95% CI = 4.28-4.63). Participants noted improved comfort with performing the cricothyrotomy after the educational lab (average improvement of 1.23±0.75). Participants specifically commented on the realism of the bleeding and skin texture; however, they also recommended a reduction in the size of the cricothyroid membrane space.  Conclusion The innovative bleeding cricothyrotomy trainer has greater fidelity and reported superiority when compared to other commonly used nonbleeding models. This trainer provides a more advanced platform to teach an infrequent yet critical procedural skill to emergency medicine residents.

PMID: 30473960 [PubMed]



from PubMed via alexandrossfakianakis on Inoreader https://ift.tt/2P4Fmw0

No comments:

Post a Comment